 |
北京总部: 4006-505-646 |
天 津 部: 4006-505-646 |
上 海 部: 4006-505-646 |
深 圳 部: 4006-505-646 |
广 州 部: 4006-505-646 |
重 庆 部: 4006-505-646 |
南 京 部: 4006-505-646 |
其它地区: 4006-505-646 | | |
|
 |
 |
硬盘公司内部使用的英文缩写
IDNF ID Not Found (LBA error) IDO Initial Drive Optimization IDS1 Interconnect Data Server IDT Initial Drive Test (SPT) IEC International Electrical Committee IMP IBI Monitoring Program IMRD Marketing requirement doc ITR Issue Tracking Report KFCI Kilo Flux Change per Inch LBA Logical Block Address LOB Line of business LOH Labor overhead LOETHE Low end of the high end LT Log Tools LTR Lock to Reference LVD Low voltage differential (SCSI) MCAL Magnetic Calibration Data MD Middle Diameter MDOS Multi-Tasking Drive Operating System MMS Margin Monitoring System, a type of data, contains drive processing status MPU Micro-Processor Unit MR Master revision MRI Magneto Resistive head Instability MSDR MTBF Mean time between failures MTTR Mean time to repair Native Mode Diagnostic mode Nonoperating Drive power off Nonrepeatable Error Data, ID, or framing error that doesn't recur when command is immediately repeated NPI NRRO Non Repeatable Run Out NRZ Non return to zero OD Outer Diameter OEM Original equipment manufacturer Operating Power on spin up, calibration complete (drive ready) ORT Ongoing Reliability Test OTP One Time Programmable PAM P list Primary defect list (IBI) PD list Push Down list PERCO PRML Enhanced Read Channel Optimization PES Position Error Signal PIO Processor input/output PM Program manager PMM Program manager meetings POR Power On Reset POST Power-on self test PRD Product specifications/requirements document PSG Personal storage group QRD Quality requirement document QVT Quality Verification Test RBB list Relocated and bad block list RCC Rack Controller Card (Xyratex) RCF Reconfiguration RDT Recalibrate Heads moved to track 0 Recoverable Error Data, ID, or framing error is recovered when host retries are enabled Repeatable Error Recurs on repeated command RLL Run length limited ROI Return on investment RPD list Reserved cylinders push down list RRC ROM Resident Code RRO Repeatable Run Out RSC Rescreen RT list Relocated Track list RVT Reliability verification test RWC Read write current RWCCS Read Write Channel Characterization Station RWE Read Write error rate SAM Error SBC Serial Bus Controller SBW Single Block Write Scan Out Serial number mismatch check SCT Sequence Control Table SDC Smart Drive Controller, 12 SDC card inside one SPT, each SDC card controls five drives SDH Select Drive and Head number register SE SECBITMAP Sector to Bitmap table SFDM SNR Signal to Noise Ratio Spare Sector Area At Inner Diameter of drive SPC Statistical Process Control, a type of data contains Servo Writer Status SPT Single Plug Test or Sectors per Track SRA Schedule risk assessment SRE System reliability engineering SRF Software Release Form STW Servo Track Writer TA Thermal Asperity (MR heads read bump friction heat as signal) TAA Track Average Amplitude TARE Transparent Auto Relocation TBMT Track Bit Map Table TD list Track descriptor list TE Test Engineering TMR Track misregistration TOC Time Offset Count (locates data following wedge) TOL TPI Tracks per inch TPM Technical program metrics Translate mode Seen by end-user | |
 |
上一篇:硬盘技术纵横谈--磁头篇 |
下一篇:硬盘技术纵横谈—马达和保护技术篇 | |
 | | |